Skip to main content

MAXScanner calculator widget

Motor Efficiency Calculator: Input, Output, Loss

Open full guide ↗

Editable live calculator

Change any input — the result updates immediately

No hidden assumptions. Inputs, units and the working stay visible so you can check the calculation.

Calculated result

90.32% efficiency

Electrical input: 8.294 kW (11.12 hp)

Shaft output: 7.492 kW (10.05 hp)

Losses: 0.803 kW (9.68% of input), which leaves the motor as about 2,740 BTU/h of heat

A measured efficiency does not establish an IE or NEMA Premium class: classes are assigned from tests at rated load, voltage and frequency.

Show the working
  1. 1. Input P = √3 × 400 V × 14.6 A × 0.82 ÷ 1000 = 8.2944 kW.
  2. 2. T = 36.14 lb·ft × 1.35582 = 48.9993 N·m.
  3. 3. ω = 2π × 1,460 rpm ÷ 60 = 152.8908 rad/s.
  4. 4. Output P = 48.9993 N·m × 152.8908 rad/s ÷ 1000 = 7.4915 kW.
  5. 5. η = 7.4915 ÷ 8.2944 × 100 = 90.32%.
  6. 6. Loss = 8.2944 − 7.4915 = 0.8029 kW.
More actions

Shared links reopen these inputs. Recent and saved calculations stay in this browser unless you clear site data.