Air Compressor CFM Calculator — Receiver Pump-Up Free Air Delivery

Estimate compressor free-air delivery from receiver volume, pressure rise, atmospheric pressure and measured pump-up time.

Inputs

Live engineering result

Idealized FAD 1.4803849 m³/min
Idealized FAD 52.2793 CFM
Pressure rise 6 bar
Receiver test volume 0.5 m³

Formula & worked example

FAD=Vreceiver·(P2abs−P1abs)/Patm/time.

A 500 L receiver rising 6 bar in 2 minutes corresponds to about 1.5 m³/min idealized free air.

Assumptions & limits

  • Assumes approximately constant receiver temperature; real compression heating biases a short pump-up test.
  • Use absolute pressure ratios and account for system demand/leaks during the test.

Frequently asked questions

What does this Air Compressor CFM Calculator calculate?

Estimate compressor free-air delivery from receiver volume, pressure rise, atmospheric pressure and measured pump-up time.

Can I use the result for equipment selection?

Use the result as an engineering screening and cross-check. Confirm final selections against manufacturer performance data, design conditions, applicable standards and local code.