Formula & worked example
FAD=Vreceiver·(P2abs−P1abs)/Patm/time.
A 500 L receiver rising 6 bar in 2 minutes corresponds to about 1.5 m³/min idealized free air.
Plant engineering calculator · Updated Sep 17, 2026
Estimate compressor free-air delivery from receiver volume, pressure rise, atmospheric pressure and measured pump-up time.
FAD=Vreceiver·(P2abs−P1abs)/Patm/time.
A 500 L receiver rising 6 bar in 2 minutes corresponds to about 1.5 m³/min idealized free air.
Estimate compressor free-air delivery from receiver volume, pressure rise, atmospheric pressure and measured pump-up time.
Use the result as an engineering screening and cross-check. Confirm final selections against manufacturer performance data, design conditions, applicable standards and local code.
Plant calculations can move materially with pressure, temperature, fluid properties, diversity and operating conditions. Visible assumptions make the result auditable.