How to use this calculator
- Enter measured or design values using the units shown beside each field.
- Review the live results and the substituted calculation steps before using the estimate.
- Check the assumptions below, then continue to a related calculator when the next engineering decision needs another model.
Worked example
A 1,000 CFM dryer using 15% purge consumes 150 CFM before translating that loss into compressor kW.
Assumptions and limits
- Purge percentage is defined here on dryer inlet flow; convert supplier data first if it is stated on a downstream-air basis.
- Use measured or OEM purge percentage at the actual dryer cycle.
- Heated, blower-purge and heat-of-compression dryers have different purge and auxiliary-power behavior.