Steam Table Calculator — Saturated & Superheated

Saturated, wet and superheated steam and compressed water properties from IAPWS-IF97: temperature, pressure, volume, density, enthalpy, entropy and cp in SI or US units.

Live calculationWorking shown

Steam Table Calculator — Saturated & Superheated

IAPWS-IF97 region 4

Saturation temperature 179.89 °C at 10 bar(a)

PropertySaturated liquid (f)Saturated vapour (g)
Temperature T179.89 °C179.89 °C
Pressure p10 bar(a)10 bar(a)
Specific volume v0.0011272 m³/kg0.19435 m³/kg
Density ρ887.13 kg/m³5.1454 kg/m³
Enthalpy h762.68 kJ/kg2,777.12 kJ/kg
Internal energy u761.56 kJ/kg2,582.77 kJ/kg
Entropy s2.1384 kJ/(kg·K)6.5850 kJ/(kg·K)
Isobaric heat capacity cp4.4051 kJ/(kg·K)2.7150 kJ/(kg·K)
Speed of sound w1,391.6 m/s500.9 m/s
  • Latent heat h_fg = 2,014.44 kJ/kg
  • Entropy of vaporisation s_fg = 4.4465 kJ/(kg·K)
How the calculator got there
  1. p = 10 bar(a) = 1 MPa (absolute)
  2. Region 4, Eq. (31): T_s(1 MPa) = 453.04 K = 179.89 °C
  3. Liquid from region 1 and vapour from region 2, both at (p, T_s)
More actions

Shared links reopen these inputs. Recent and saved calculations stay in this browser unless you clear site data.

Saturated steam table by pressure, 1 to 40 bar(a)

Computed by this calculator from IAPWS-IF97. h_f is the saturated liquid, h_g the saturated vapour, h_fg the latent heat.

p (bar(a))T_s (°C)h_f (kJ/kg)h_fg (kJ/kg)h_g (kJ/kg)v_g (m³/kg)ρ_g (kg/m³)
199.61417.42,257.52,674.91.69400.590
2120.21504.72,201.62,706.20.88571.129
3133.53561.52,163.42,724.90.60581.651
5151.84640.22,107.92,748.10.37482.668
7164.95697.12,065.62,762.70.27283.666
10179.89762.72,014.42,777.10.19435.145
15198.30844.71,946.32,791.00.13177.593
20212.38908.61,889.82,798.40.099610.042
30233.861,008.41,794.92,803.30.066715.001
40250.361,087.41,713.52,800.90.049820.090

Which states the calculator covers

Region 1: liquid water from 0 °C to 350 °C, from the saturation pressure up to 1,000 bar. Region 2: steam from 0 °C to 800 °C, up to the saturation pressure below 350 °C, up to the B23 line between 350 °C and 590 °C (165.29 bar at 350 °C, 1,000 bar at 590 °C) and up to 1,000 bar above it. Region 4: the saturation line from 0 °C to 350 °C. Not covered: region 3 around the critical point and region 5 above 800 °C.

Checked against the IAPWS verification tables

The release gives test values so that programmers can check their code. This calculator reproduces all nine digits of each one, for example region 1 at 300 K and 3 MPa: h = 115.331273 kJ/kg; region 2 at 700 K and 30 MPa: v = 0.00542946619 m³/kg; saturation at 500 K: p_s = 2.63889776 MPa.

Sources

  1. IAPWS R7-97(2012): Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam
  2. NIST: SI units, conversion factors for the British thermal unit (IT) and the pound

Steam properties at 10 bar(a), and how they are computed

Saturated steam at 10 bar(a) condenses and boils at 179.89 °C. One kilogram of the saturated liquid holds 762.7 kJ, the saturated vapour 2,777.1 kJ, so 2,014.4 kJ/kg is released when the steam condenses. The vapour takes up 0.1943 m³/kg (5.145 kg/m³). Heat the same steam to 250 °C at 10 bar(a) and it is superheated by 70.11 K: 2,943.2 kJ/kg, 0.2327 m³/kg and 6.9266 kJ/(kg·K). The calculator gives these numbers for any pressure or temperature it covers, using the industrial formulation the power industry uses for steam tables, IAPWS-IF97: region 1 for liquid water, region 2 for steam and region 4 for the saturation line. It works up to 100 MPa and 800 °C, and on the saturation line up to 350 °C (165.29 bar(a)).

How to use this calculator

1

Pick what you know: the pressure of saturated steam, its temperature, pressure and temperature for superheated steam or compressed water, or pressure and dryness fraction x for wet steam.

2

Enter the pressure and choose its unit. Gauge units (bar(g), psig) add a standard atmosphere of 1.01325 bar, so use absolute units when you know the real atmospheric pressure.

3

Enter the temperature in °C, °F or K, and the quality x between 0 (all liquid) and 1 (all vapour) for wet steam.

4

Choose SI or US units for the results, read the table, and open one of the steam calculators with these values filled in.

Where people use it

  • •Latent heat for a heat exchanger or a steam trap check: 2,014.4 kJ/kg at 10 bar(a), 2,257.5 kJ/kg at 1 bar(a).
  • •Specific volume for steam velocity, pipe and separator sizing, without copying it from a printed table.
  • •Superheat and enthalpy for a turbine, desuperheater or superheater duty.
  • •Wet steam enthalpy and density from a measured or assumed dryness fraction.
  • •Coursework in thermodynamics: checking a hand interpolation against the formulation the tables are printed from.

Example: what superheating to 250 °C adds at 10 bar(a)

At 10 bar(a) the saturated vapour has 2,777.1 kJ/kg at 179.89 °C. At 250 °C the calculator gives 2,943.2 kJ/kg, so superheating by 70.11 K adds 166.1 kJ/kg. The average cp over that range is 166.1 ÷ 70.11 = 2.369 kJ/(kg·K), while cp at 250 °C itself is only 2.212 kJ/(kg·K). A rule-of-thumb cp of 2.08 would give 145.8 kJ/kg, 12 % too little. For 5,000 kg/h of steam that is the difference between 230.7 kW and 202.6 kW of superheater duty.

Where the calculator stops

  • •Region 3 (around the critical point: above 350 °C and above the B23 line, roughly 165–1,000 bar) and region 5 (800–2,000 °C) are not included. The calculator says so instead of giving a number.
  • •Below 0 °C (273.15 K) and above 100 MPa the IF97 equations used here do not apply.
  • •A state exactly on the saturation line has no single phase. Use saturation or wet steam mode for it.
  • •Gauge pressure is converted with a standard atmosphere (1.01325 bar, 14.696 psi). At high altitude the real atmosphere is lower, so enter absolute pressure.
  • •Thermodynamic properties only: no viscosity or thermal conductivity, and pure water only, not boiler water with dissolved solids.
  • •IF97 is the industrial formulation. For scientific work and calibration IAPWS publishes a separate scientific formulation, IAPWS-95.

Frequently asked questions

What is the saturation temperature of steam at 10 bar?+

At 10 bar absolute it is 179.89 °C. At 10 bar gauge, which is 11.01 bar absolute with a standard atmosphere, it is 184.12 °C. Check which one your gauge or drawing means before you read the table.

How do I read a steam table?+

For saturated steam look up the pressure or the temperature: the row gives the other one, then v, h and s for the saturated liquid (subscript f) and the saturated vapour (g), and the latent heat h_fg = h_g − h_f. For superheated steam you need both pressure and temperature. This calculator does the lookup without interpolation, because it evaluates the IAPWS-IF97 equations the tables are printed from.

What is the enthalpy of superheated steam at 10 bar and 250 °C?+

2,943.2 kJ/kg (1,265.4 Btu/lb), with a specific volume of 0.2327 m³/kg, a density of 4.297 kg/m³ and an entropy of 6.9266 kJ/(kg·K). The steam is 70.11 K above its saturation temperature of 179.89 °C.

How do I calculate wet steam with a dryness fraction?+

Mix the saturated liquid and vapour values in proportion to x: h = h_f + x (h_g − h_f). At 10 bar(a) and x = 0.9: 762.7 + 0.9 × 2,014.4 = 2,575.7 kJ/kg, and v = 0.1750 m³/kg. Choose wet steam mode and the calculator does this for v, ρ, h, u and s.

Why does the calculator stop at 350 °C on the saturation line?+

Above 350 °C (16.529 MPa) saturated water and steam lie in IF97 region 3, which uses a different equation in density and temperature. This calculator implements regions 1, 2 and 4 only, so it shows the saturation temperature or pressure there but not the liquid and vapour properties.

Are the results the same as a printed steam table?+

Yes, where the printed table uses IAPWS-IF97. The code reproduces the IAPWS verification values for regions 1, 2 and 4 (Tables 5, 15, 35 and 36) to all nine published digits. Older tables based on IFC-67 can differ in the last digits.

Can I get the steam table in US units?+

Yes. Enter pressure in psia or psig and temperature in °F, and switch the results to US units: Btu/lb, Btu/(lb·°F), ft³/lb and lb/ft³. At 100 psia saturated steam is at 327.82 °F with h_g = 1,187.5 Btu/lb and v_g = 4.432 ft³/lb.

Semantic next steps

Continue the calculation

These links move to a different input, formula or project stage rather than a keyword variation of this page.

Electrical & Engineering Calculators

Steam Velocity Calculator — Mass Flow, Specific Volume & Pipe Velocity

Calculate volumetric steam flow and line velocity from mass flow, specific volume and actual pipe inside diameter, with target-velocity comparison.

Steam Pipe Sizing Calculator — Velocity & Bore

Size a steam line from mass flow, entered steam specific volume and target velocity, or check velocity for an entered inside diameter.

Steam Superheat Energy Calculator — Heat Duty

Calculate sensible superheat duty above saturation from steam flow, superheat temperature rise and entered vapor heat capacity.

Flash Steam Calculator — Flash % & Recovery

Estimate flash-steam fraction when saturated condensate drops to a lower pressure, plus flash flow, remaining condensate and recoverable flash energy using an explicit enthalpy-property approximation.

Steam Quality Calculator — Dryness Fraction

Calculate wet-steam quality from mixture enthalpy and saturated liquid/vapor enthalpies, or mixture enthalpy from entered dryness fraction.

Steam Desuperheating Water Calculator — Spray Water Flow & Outlet Steam

Estimate spray-water flow for steam desuperheating from a transparent steady-state energy balance.

Boiler Steam Output Calculator — Fuel Input, Efficiency & Steam Generation

Estimate useful boiler duty and steam generation from fuel input, boiler efficiency, feedwater enthalpy and steam enthalpy.

Steam Cost Calculator — Fuel, Water & Chemicals

Estimate true steam production cost from boiler enthalpy rise and efficiency, fuel energy price, makeup-water/chemical cost, auxiliary electricity and condensate-return credit. Returns cost per tonne and per 1,000 lb plus annual spend.

Free publisher widget

Put this calculator on your website

Give readers the live calculator without rebuilding the math. Copy the responsive embed in one click, or customize width, height, border and corner radius before publishing. The branded MAXScanner attribution stays visible.

Preview

Calculator embed HTML

Paste this code into your page. Focus the code box to select it manually.

Keep the result connected to the real job

MAXScanner keeps the formula and assumptions beside the result so you can verify the number before using it in a drawing, estimate, specification, worksheet or document. Where a supplier, manufacturer, drawing or applicable standard owns a requirement, that source remains authoritative.