How to use this calculator
- Enter measured or design values using the units shown beside each field.
- Review the live results and the substituted calculation steps before using the estimate.
- Check the assumptions below, then continue to a related calculator when the next engineering decision needs another model.
Worked example
500 SCFM at 100 psig occupies far less line volume than 500 actual CFM; pressure correction prevents a misleading velocity.
Assumptions and limits
- Ideal-gas scaling is used for screening.
- Pressure varies along a real line; use a pressure-drop model for final distribution sizing.
- Use actual inside diameter and review velocity together with pressure drop; DOE/ORNL guidance uses low header velocities to limit distribution loss.