Skip to main content

Find your next tool

Electrical & Engineering Calculators

Conduit Offset Calculator — Bend Spacing, Shrink & Marks

Calculate equal-angle conduit offset bend spacing and published field shrink from Greenlee-style multiplier constants, with optional bend-mark and available-length checks.

Live calculationWorking shown

Editable live calculator

Change any input — the result updates immediately

No hidden assumptions. Inputs, units and the working stay visible so you can check the calculation.

Calculated result

12 in between bend centers

Published field multiplier: 2 ×

Offset shrink allowance: 1.5 in (0.25 per unit of offset depth)

Enter a first-mark position to calculate the second mark.

Shrink is reported separately so it can be applied to the job-specific reference.

No available layout length entered.

Show the working
  1. 1. Center-to-center spacing = 6 × 2 = 12 in.
  2. 2. Shrink = 6 × 0.25 = 1.5 in.
  3. 3. Mark positions depend on the chosen first reference.
More actions

Shared links reopen these inputs. Recent and saved calculations stay in this browser unless you clear site data.

The calculation, without hidden assumptions

Lay out a two-bend equal-angle conduit offset without mixing in bender-specific stub deduct. Enter offset depth and a published field angle; MAXScanner returns center-to-center bend spacing, shrink allowance and optional mark positions in inches or millimetres.

How to use this calculator

1

Measure the perpendicular offset depth required.

2

Choose the equal bend angle you will make in opposite directions.

3

Use the calculated center-to-center spacing to place the second bend relative to the first.

4

When working toward an obstruction, apply the reported shrink using the procedure for your bender and layout direction.

5

Verify shoe markings, springback, minimum radius and project/code requirements before bending.

Where people use it

  • •Laying out a 30° offset into a box or around an obstruction.
  • •Comparing shallow and steep offset layouts before choosing an angle.
  • •Checking whether the required center-to-center spacing fits the available straight run.
  • •Converting the same dimensionless field method between inch and metric job measurements.

Example: 6-inch offset at 30°

Greenlee’s published 30° field multiplier is 2.0 and shrink is 1/4 inch per inch of offset depth. Spacing = 6 × 2 = 12 in. Shrink = 6 × 1/4 = 1.5 in.

What the result does not assume

  • •This calculator uses published field-table constants rather than silently mixing exact trigonometric shrink with rounded bender-chart values. Follow one method consistently.
  • •Stub-up deduct, gain, shoe alignment, ram travel and springback are bender-specific and are intentionally not inferred here.
  • •The two bends must be equal and opposite and kept in the same plane; this owner does not model dog-leg correction.
  • •Verify conduit type, bender/shoe instructions, minimum bend radius and the total bend allowance between pull points for the actual installation.
  • •Metric mode scales dimensions only; multiplier and shrink ratios remain dimensionless.

Frequently asked questions

What is the multiplier for a 30 degree conduit offset?+

The published Greenlee field table uses 2.0, so center-to-center spacing is twice the offset depth.

How much shrink does a 30 degree offset have?+

The published field value is 1/4 unit of shrink per unit of offset depth; a 6-inch offset therefore uses 1.5 inches.

Why not use exact trigonometry for every displayed field value?+

Bender field tables publish rounded multipliers and shrink constants. Mixing exact and field-table values can produce inconsistent marks, so this owner clearly uses the published field method.

Does this calculate stub-up deduct?+

No. Stub deduct and alignment references depend on the actual bender or shoe and should come from its markings or manual.

Can I calculate in millimetres?+

Yes. The constants are ratios, so spacing and shrink scale in the same unit as the entered offset depth.

Does an offset count toward total conduit bend degrees?+

Yes. An equal two-bend offset contributes both bend angles to the run; verify the applicable raceway rules and pull-point layout separately.

Semantic next steps

Continue the calculation

These links move to a different input, formula or project stage rather than a keyword variation of this page.

View the full collection

Conduit Fill Calculator — Wire & Cable Raceway Fill

Calculate conduit fill from actual cable outside diameters and raceway inside diameter, check 53/31/40% conductor-count limits or a custom limit, and reverse-solve minimum ideal ID.

Open

Ampacity Derating Calculator — Temperature & Conductor Adjustment

Apply ambient-temperature correction and current-carrying-conductor adjustment to an entered starting ampacity, then compare an optional terminal ceiling and load.

Open

Cable Pulling Tension Calculator — Bend & Sidewall Pressure

Estimate cable pulling tension through straight conduit and a bend, compare pull direction, and screen sidewall pressure against manufacturer-entered limits.

Open

Wireway Fill Calculator — 20% Fill & >30 Conductor Check

Calculate metal or nonmetallic wireway conductor fill against the 20% interior-area rule, minimum required area, >30 current-carrying-conductor flag and optional splice/tap point check.

Open

Pull Box Sizing Calculator — NEC 314.28 Straight, Angle & U Pulls

Calculate minimum pull-box and junction-box dimensions for 4 AWG and larger conductors using NEC 314.28 straight-pull, angle/U-pull and same-conductor raceway-spacing rules.

Open

Ohm's Law Calculator — Volts, Amps, Ohms and Watts

Calculate voltage, current, resistance and power from any two positive electrical values using Ohm's Law and Watt's Law.

Open

Reactance Calculator — Inductive XL, Capacitive XC & LC Resonance

Calculate inductive or capacitive reactance, reverse-solve frequency or component value, or find ideal LC resonant frequency with engineering-unit inputs and visible formulas.

Open

Internal Resistance Calculator — Battery Load Test, Two Points & Voltage Sag

Estimate a source or battery internal resistance from open-circuit and loaded voltage, from two load points, or run the internal-resistance model forward to check sag, loss and efficiency.

Open

More in this calculator collection

Browse nearby calculators in the same topic cluster so related pages reinforce each other instead of sitting as isolated URLs.

Free publisher widget

Put this calculator on your website

Give readers the live calculator without rebuilding the math. Copy the responsive embed in one click, or customize width, height, border and corner radius before publishing. The branded MAXScanner attribution stays visible.

Preview

Calculator embed HTML

Paste this code into your page. Focus the code box to select it manually.

Keep the result connected to the real job

MAXScanner keeps the formula and assumptions beside the result so you can verify the number before using it in a drawing, estimate, specification, worksheet or document. Where a supplier, manufacturer, drawing or applicable standard owns a requirement, that source remains authoritative.