Deaerator Steam Consumption Calculator — Heat Balance & Steam Demand
Estimate deaerator heating-steam demand from feedwater flow and inlet/outlet enthalpy using a transparent steady-state energy balance.
Inputs
Live results
- Heating steam 2.8632479 t/h
- Steam/feedwater ratio 14.316239%
- Heating duty 1,861.1111 kW
Formula
mₛ=mw(hout−hin)/(hsteam−hout).
Worked example
20 t/h feedwater heated from 105 to 440 kJ/kg with 2,780 kJ/kg steam needs about 2.86 t/h steam.
Assumptions and limits
- Use validated enthalpies for actual pressure and temperature.
- Venting and radiation losses are excluded unless included in a design margin.