Boiler Feedwater Heating Duty Calculator

Calculate sensible feedwater heating duty, annual thermal energy and steam-equivalent heating load.

Inputs

Results

Feedwater heating duty 697.67 kW

Steam-equivalent heating 1141.64 kg/h

Annual thermal energy 4186000.00 kWh

Temperature rise 60.00 °C

Method, assumptions & example

Duty = mass flow × Cp × temperature rise. A 10,000 kg/h feedwater stream heated from 30°C to 90°C needs about 698 kW sensible duty with Cp 4.186 kJ/kg·K. Steam equivalent is an energy screen; actual heaters require steam-table enthalpies and drain/subcooling checks.

FAQs

Is this a final design calculation?

No. Use it for transparent screening and verify equipment, controls and thermodynamic properties against site/OEM data.

What units are used?

The inputs state practical SI units explicitly and outputs are normalized to kW, kWh and kg/h where applicable.