Boiler Feedwater Heating Duty Calculator
Calculate sensible feedwater heating duty, annual thermal energy and steam-equivalent heating load.
Inputs
Results
Feedwater heating duty 697.67 kW
Steam-equivalent heating 1141.64 kg/h
Annual thermal energy 4186000.00 kWh
Temperature rise 60.00 °C
Method, assumptions & example
Duty = mass flow × Cp × temperature rise. A 10,000 kg/h feedwater stream heated from 30°C to 90°C needs about 698 kW sensible duty with Cp 4.186 kJ/kg·K. Steam equivalent is an energy screen; actual heaters require steam-table enthalpies and drain/subcooling checks.
FAQs
Is this a final design calculation?
No. Use it for transparent screening and verify equipment, controls and thermodynamic properties against site/OEM data.
What units are used?
The inputs state practical SI units explicitly and outputs are normalized to kW, kWh and kg/h where applicable.