What “standard” means on each datasheet
The same 500 Nm³/h of dry gas under each definition. Two datasheets disagree because their reference conditions differ, not because the gas changed: 1 Nm³/h is 0.6221 SCFM at 60 °F but 0.6400 at ISO 1217.
| Standard | 500 Nm³/h is | Conditions | Source |
|---|---|---|---|
| DIN 1343 normal (Nm³) | 500.00 Nm³/h · 294.29 ft³/min | 0 °C · 1.01325 bar(a) · dry | DIN, ISO |
| ISO 13443 standard (Sm³) | 527.46 Sm³/h · 310.45 SCFM | 15 °C · 1.01325 bar(a) · dry | ISO |
| ISO 1217 / CAGI free air | 543.72 Sm³/h · 320.02 SCFM | 20 °C · 1 bar(a) · dry | Compressed Air Challenge / U.S. DOE |
| ASME standard air | 540.96 Sm³/h · 318.40 SCFM | 68 °F (20 °C) · 14.7 psia (1.01353 bar(a)) · RH 36 % | PD Blowers (Roots SCFM vs ACFM guidebook) |
| US 60 °F base | 528.47 Sm³/h · 311.05 SCFM | 60 °F (15.56 °C) · 14.696 psia (1.01325 bar(a)) · dry | eCFR |
| US natural gas | 527.25 Sm³/h · 310.33 SCFM | 60 °F (15.56 °C) · 14.73 psia (1.0156 bar(a)) · dry | eCFR |
Worked examples
Each line is worked out by this converter with the data in the tables on this page.
- 100 SCFM (60 °F, 14.696 psia) at 7 bar(g) and 35 °C at sea level: 13.50 ACFM, 22.93 m³/h actual. Read as ISO 1217 free air, 13.12 ACFM; as DIN 1343 normal conditions, 14.26 ACFM.
- 500 Nm³/h in the same line: 71.32 m³/h actual, 41.98 ACFM.
- A blower rated 1,000 SCFM of ASME standard air (68 °F, 14.7 psia, 36 % RH), at a 14.18 psia barometer, 80 °F and 70 % RH: 1,078.5 ACFM. The vapour takes 0.355 psia of the inlet pressure.
- Mass of 500 Nm³/h: air 646.12 kg/h, nitrogen 624.91, oxygen 713.81, carbon dioxide 981.74, methane 357.87, hydrogen 44.97.
Compressor intake by altitude
Standard-atmosphere pressure (U.S. Standard Atmosphere 1976) and the inlet volume of 100 SCFM of ISO 1217 free air drawn in at 25 °C.
| Altitude | Atmospheric pressure | 100 SCFM (ISO 1217) at 25 °C |
|---|---|---|
| 0 m (0 ft) | 1.0133 bar(a) · 14.7 psia | 100.38 ACFM |
| 500 m (1,640 ft) | 0.9546 bar(a) · 13.85 psia | 106.54 ACFM |
| 1,000 m (3,281 ft) | 0.8988 bar(a) · 13.04 psia | 113.16 ACFM |
| 1,500 m (4,921 ft) | 0.8456 bar(a) · 12.26 psia | 120.28 ACFM |
| 2,000 m (6,562 ft) | 0.795 bar(a) · 11.53 psia | 127.93 ACFM |
| 2,500 m (8,202 ft) | 0.7469 bar(a) · 10.83 psia | 136.17 ACFM |
| 3,000 m (9,843 ft) | 0.7012 bar(a) · 10.17 psia | 145.04 ACFM |
When the ideal gas stops being good enough
Compressibility factor Z at 20 °C from NIST data; air is estimated from nitrogen, oxygen and argon. Z = 1 is an ideal gas, and the actual volume scales with Z.
| Gas | Z at 1 bar(a) | Z at 11 bar(a) | Z at 21 bar(a) | Z at 51 bar(a) | 1 % off from about |
|---|---|---|---|---|---|
| Air (estimate) | 0.9997 | 0.9965 | 0.9938 | 0.9883 | 38 bar(a) |
| Nitrogen (N₂) | 0.9998 | 0.9976 | 0.9960 | 0.9940 | 125 bar(a) |
| Oxygen (O₂) | 0.9993 | 0.9925 | 0.9859 | 0.9681 | 15 bar(a) |
| Carbon dioxide (CO₂) | 0.9947 | 0.9397 | 0.8794 | 0.6299 | 2 bar(a) |
| Methane (CH₄), natural gas | 0.9981 | 0.9799 | 0.9618 | 0.9101 | 5.5 bar(a) |
| Hydrogen (H₂) | 1.0006 | 1.0065 | 1.0125 | 1.0306 | 17 bar(a) |
Sources: DIN, DIN 1343:1990-01 Referenzzustand, Normzustand, Normvolumen; Begriffe und Werte; ISO, ISO 13443:1996 Natural gas — Standard reference conditions (clause 3, notes 4–5); Compressed Air Challenge / U.S. DOE, Fact Sheet 8: Packaged compressor efficiency ratings (ISO 1217, CAGI data sheets); PD Blowers (Roots SCFM vs ACFM guidebook), SCFM vs ACFM with sample calculation; eCFR, 43 CFR 3174.1, base pressure and base temperature; eCFR, 30 CFR 250.1203, gas measurement; IAPWS, IAPWS-IF97 (R7-97(2012)), saturation pressure, Eq. 30; NOAA, NASA, USAF, U.S. Standard Atmosphere, 1976, Eq. 33a and Tables 3–4; NIST Chemistry WebBook, Thermophysical properties of fluid systems (isotherms at 20 °C) and molecular weights; NIST CODATA, Molar gas constant R = 8.314 462 618 J/(mol·K). Sources read on November 18, 2026.
How standard and actual flow are converted
ACFM = SCFM × (P standard ÷ P actual) × (T actual ÷ T standard), with absolute pressures and absolute temperatures. 100 SCFM of dry air at 7 bar(g) and 35 °C fills 13.50 ft³ a minute in the pipe when SCFM means 60 °F and 14.696 psia, and 13.12 when it means the ISO 1217 compressor reference of 20 °C and 1 bar. Metric flows follow the same rule: 500 Nm³/h (0 °C, 1.01325 bar) is 71.32 m³/h in that line, 311.05 SCFM at 60 °F and 320.02 at ISO 1217. Choose the reference printed on your datasheet and the converter gives the other side, the same gas under every common standard and the mass flow.
How to use this calculator
Type the flow, choose its unit and say whether it is a standard flow (SCFM, Nm³/h, Sm³/h) or the actual flow in the line (ACFM, m³/h).
Choose the standard your datasheet or meter uses. Nm³ means 0 °C and 1.01325 bar; ISO 1217 and CAGI compressor sheets use 20 °C, 1 bar and dry air.
Type the line pressure, mark it gauge or absolute, and the gas temperature. For gauge readings well above sea level, set the site altitude or a barometer reading.
Add the relative humidity for moist intake air; leave 0 for dried compressed air and bottled gases.
Choose the gas for the mass flow, then read the table under every standard, copy the result or take the flow to the pipe velocity calculator.
Where people use it
- •Checking a compressor rated 320 “SCFM” to ISO 1217 against a process that asks for 500 Nm³/h: both figures describe the same air.
- •Sizing a pipe, filter or dryer for the volume that really flows at 7 bar(g), where 100 SCFM is only about 13.5 ft³ a minute.
- •Turning a blower duty at a plant 1,500 m up into the inlet volume the machine must move: 100 SCFM (ISO 1217) is 120.28 ACFM at 25 °C there.
Example: one compressed-air line, three “standards”
A dryer is sized for 100 SCFM; the line runs at 7 bar(g) and 35 °C at sea level, 116.22 psia. With SCFM at 60 °F and 14.696 psia: 100 × (14.696 ÷ 116.22) × (308.15 K ÷ 288.71 K) = 13.50 ACFM, or 22.93 m³/h. Read the same 100 as ISO 1217 free air (20 °C, 1 bar) and the line carries 13.12 ACFM; as DIN 1343 normal conditions, 14.26. The dry air weighs 207.73 kg/h on the 60 °F reading.
Where an ideal-gas conversion stops being exact
- •The conversion treats the gas as ideal. From NIST data at 20 °C, air stays within about 0.3 % of ideal at 7 bar(g), but carbon dioxide is 1 % off from about 2 bar(a), methane from about 5.5 bar, oxygen from 15 bar and hydrogen from 17 bar. Above those pressures, type Z from a property table.
- •A datasheet that prints SCFM or Sm³/h without its reference can mean any of the definitions here. For 100 SCFM at 7 bar(g) and 35 °C the actual flow ranges from 13.12 to 14.26 ACFM, 8.7 % apart, so ask the supplier which one applies.
- •Free air delivery (FAD) is the volume a compressor draws in. ISO 1217 and CAGI data sheets refer it to 1 bar, 20 °C and dry air; at a hot or high intake the machine moves the same volume but less air.
- •Humidity uses the IAPWS-IF97 vapour pressure from 0 °C upward. Below 0 °C the term is left out: water vapour there is under 0.61 kPa, at most 0.6 % of sea-level pressure.
- •Altitude gives the standard-atmosphere pressure, not the barometer on the day. Type a barometer reading when you have one.
- •Mass flow counts the dry gas only. Natural gas is mostly methane, but its molar mass is usually a little above the 16.04 g/mol used here, so treat its mass flow as an estimate.
Frequently asked questions
What is the difference between SCFM and ACFM?+
SCFM is gas counted at a fixed reference pressure and temperature, so it measures the amount of gas. ACFM is the volume that gas takes where it flows. 100 SCFM (60 °F, 14.696 psia) is 13.50 ACFM in a line at 7 bar(g) and 35 °C, and more than 100 ACFM at a hot or high-altitude intake.
How do I convert SCFM to ACFM?+
Multiply by the standard absolute pressure over the actual absolute pressure, then by the actual absolute temperature over the standard one. For the 60 °F standard: ACFM = SCFM × (14.696 ÷ psia) × ((°F + 459.67) ÷ 519.67). At 100 psig and 80 °F, 100 SCFM is 100 × (14.696 ÷ 114.696) × (539.67 ÷ 519.67) = 13.31 ACFM.
How do I convert Nm³/h to SCFM?+
Divide by 1.6075 for SCFM at 60 °F and 14.696 psia: 500 Nm³/h is 311.05 SCFM. The divisor depends on the standard: at ISO 1217 (20 °C, 1 bar) the same 500 Nm³/h is 320.02 SCFM, as ASME standard air 318.40. Multiplying by 0.5886, the plain m³ to ft³ factor, ignores the temperature change and gives 294.29, 5.4 % low.
What is the difference between Nm³ and Sm³?+
Both are amounts of gas. Nm³ (normal) is at 0 °C and 1.01325 bar (DIN 1343). Sm³ (standard) is usually at 15 °C and 1.01325 bar (ISO 13443), so 1 Nm³ = 1.0549 Sm³. Compressor sheets that say “standard” often mean 20 °C and 1 bar instead, so check the footnote.
How do I convert Nm³/h to actual m³/h?+
Multiply by 1.01325 ÷ absolute pressure in bar and by (°C + 273.15) ÷ 273.15. At 7 bar(g) and 35 °C at sea level: 500 × (1.01325 ÷ 8.01325) × (308.15 ÷ 273.15) = 71.32 m³/h. In German this is Normkubikmeter to Betriebskubikmeter.
What is FAD on a compressor datasheet?+
Free air delivery: the air a compressor supplies, given as the volume it takes at the inlet. ISO 1217 and CAGI data sheets refer it to 1 bar, 20 °C and dry air, so 10 m³/min FAD is 551.75 Nm³/h or 343.24 SCFM at 60 °F.
Does altitude change ACFM?+
Yes. The standard atmosphere is 0.8456 bar at 1,500 m, so 100 SCFM (ISO 1217) drawn in at 25 °C takes 120.28 ACFM there and 145.04 at 3,000 m. A compressor that moves a fixed inlet volume therefore delivers less air at altitude.
Is anything uploaded?+
No. The conversion runs in your browser; the numbers you type stay on your device.
Semantic next steps
Continue the calculation
These links move to a different input, formula or project stage rather than a keyword variation of this page.
Compressed Air Velocity Calculator — SCFM & Bore
Convert free-air flow to approximate line-condition flow and velocity using absolute-pressure ratio, pipe inside diameter and temperature ratio.
Compressed Air Pressure Drop Calculator — Darcy Friction, Velocity & Downstream Pressure
Estimate compressed-air pipe friction with pressure-corrected actual flow, Reynolds number and Darcy-Weisbach loss. Returns velocity, Reynolds number, friction factor, pressure drop and downstream pressure.
Air Receiver Sizing Calculator — CFM & Hold Time
Size a compressed-air receiver from peak demand, compressor supply, usable pressure band and required hold time. Returns required storage in litres, cubic metres, cubic feet and US gallons, plus practical standard-size guidance.
Air Compressor CFM Calculator — Receiver Pump-Up
Estimate compressor free-air delivery from receiver volume, pressure rise, atmospheric pressure and measured pump-up time.
Gas m³ to kWh Calculator: Meter Readings to Bill
Gas meter readings to kWh and a bill: UK m³ or imperial ft³ (1.02264 × calorific value ÷ 3.6), Germany, Austria, France, Italy, Spain, Netherlands and US therms. Reverse kWh → m³.
Ideal Gas Law Calculator — Solve P, V, n or T with Unit Conversion
Enter any three ideal-gas variables and solve the fourth. Pressure, volume and temperature unit choices are converted to SI internally before PV=nRT is applied.
Air Density Calculator — Temp, Pressure, Humidity
Calculate moist-air density from temperature, barometric pressure and relative humidity using dry-air and water-vapor partial pressures.
Free publisher widget
Put this calculator on your website
Give readers the live calculator without rebuilding the math. Copy the responsive embed in one click, or customize width, height, border and corner radius before publishing. The branded MAXScanner attribution stays visible.
Calculator embed HTML
Paste this code into your page. Focus the code box to select it manually.
Keep the result connected to the real job
MAXScanner keeps the formula and assumptions beside the result so you can verify the number before using it in a drawing, estimate, specification, worksheet or document. Where a supplier, manufacturer, drawing or applicable standard owns a requirement, that source remains authoritative.