The calculation, without hidden assumptions
Topping up a 1,200 sq ft attic from R-19 to R-49 means adding R-30, and the bag count depends on what you blow in: 18 bags of Owens Corning AttiCat (14.6 bags per 1,000 sq ft, at least 10.75 in deep), 17 bags of CertainTeed InsulSafe SP (13.8 per 1,000 sq ft, 11.5 in) or 47 bags of GreenFiber SANCTUARY cellulose (38.6 per 1,000 sq ft, 8.9 in blown, 8.3 in after settling). Those figures come from each maker's coverage chart, and they show why calculators built on one "square feet per bag" number disagree: a 25 lb bag of SANCTUARY covers 44.2 sq ft at R-19 but 14.1 sq ft at R-49. Pick your product, the R-value you want and what is already in the attic; the calculator reads the right row of that chart and interpolates when you add an in-between amount. A second mode counts packages of batts for 16 in or 24 in framing from Owens Corning's EcoTouch package chart. Metric readers get square metres, centimetres and RSI.
How to use this calculator
Measure the attic floor over the heated rooms (length × width, not the roof slope) or the wall area, in feet or metres.
Choose the target. ENERGY STAR's retrofit table gives R-30 for climate zone 1, R-49 for zones 2–3 and R-60 for zones 4–8 when an attic has no insulation; your local code may ask for a different figure.
Enter what is already there, as an R-value or as a depth and type. About 6 in of old fiberglass batts is R-19, the example GreenFiber's guide uses.
Pick the bag you will buy, or switch to batts and pick the R-value and the framing spacing. Read the bags or packages, the depth to blow and the weight to carry.
Where people use it
- •Topping up attic insulation with a rented blowing machine
- •Insulating open 2×4 or 2×6 walls, a garage or a bonus room with batts before the drywall goes up
- •Comparing fiberglass and cellulose quotes for the same R-value
Worked example: 1,200 sq ft attic from R-19 to R-49
The attic is 40 × 30 ft (1,200 sq ft) with about 6 in of old fiberglass batts, R-19. Reaching R-49 means adding R-30. AttiCat's chart asks for 14.6 bags per 1,000 sq ft at R-30: 1,200 × 14.6 ÷ 1,000 = 17.52, rounded up to 18 bags blown at least 10.75 in deep, 495 lb of insulation to carry up at 27.5 lb a bag. InsulSafe SP needs 13.8 bags per 1,000 sq ft: 16.56, so 17 bags at 11.5 in. GreenFiber SANCTUARY cellulose needs 38.6: 46.32, so 47 bags blown 8.9 in deep, settling to 8.3 in. Aiming for R-60 in climate zone 5 instead means adding R-41, between the R-38 and R-44 rows of the AttiCat chart; the calculator interpolates 20.7 bags per 1,000 sq ft and 14.5 in, which is 25 bags.
| Target | AttiCat 27.5 lb: bags per 1,000 sq ft | AttiCat: sq ft per bag | InsulSafe SP 31 lb: bags per 1,000 sq ft | InsulSafe SP: sq ft per bag | SANCTUARY 25 lb: bags per 1,000 sq ft | SANCTUARY: sq ft per bag |
|---|---|---|---|---|---|---|
| R-19 (RSI 3.3) | 9 | 110.7 | 8.6 | 116.2 | 22.6 | 44.2 |
| R-30 (RSI 5.3) | 14.6 | 68.5 | 13.8 | 72.5 | 38.6 | 25.9 |
| R-38 (RSI 6.7) | 19 | 52.6 | 17.9 | 55.7 | 52.6 | 19 |
| R-49 (RSI 8.6) | 25 | 39.9 | 23.5 | 42.6 | 70.8 | 14.1 |
| R-60 (RSI 10.6) | 31.5 | 31.8 | 28.9 | 34.5 | 86 | 11.6 |
What the result does not assume
- •Coverage charts belong to one product. A "square feet per bag" figure without the product and the R-value means little: AttiCat covers 68.5 sq ft per bag at R-30 and 39.9 at R-49, SANCTUARY cellulose 25.9 and 14.1. Read the chart printed on the bag you buy, because makers revise them; if it differs, choose "Other bag" and type its coverage.
- •The bags and the depth both count. Each chart here says the stated R-value needs the minimum number of bags and at least the minimum thickness, so blowing the insulation fluffier to reach the depth with fewer bags gives a lower R-value. Staple attic rulers to the joists before you start. Cellulose is charted at its settled thickness, which GreenFiber puts at 90% of the blown depth.
- •Before blowing, keep the soffit vents open with baffles (vent chutes), keep insulation at least 3 in from recessed lights that are not IC-rated and from flues and chimneys, and build a dam around the attic hatch, as the GreenFiber and CertainTeed instructions say. Sealing air leaks first is cheaper than extra inches.
- •Targets are guidance, not code. ENERGY STAR's table follows the 2021 IECC and lists cost-effective levels for US climate zones; your building department sets the legal minimum. Other countries use other rules and units: Canada states RSI (m²·K/W), and Australia and New Zealand label products with metric R-values, the same unit as RSI, so an R6.0 ceiling batt there is about R-34 in US units.
- •Batt packages come from Owens Corning's EcoTouch fact sheet (March 2016). Sizes and pieces per package vary between stores, so check yours or enter it as another package. Do not compress batts: an R-19 batt is 6-1/4 in thick, more than a 2×6 cavity (5-1/2 in), which R-21 batts are made for.
Frequently asked questions
How many bags of blown-in insulation do I need?+
Multiply the attic area by the maker's bags per 1,000 sq ft for the R-value you are adding. Bringing 1,000 sq ft of bare joists to R-49 takes 25 bags of AttiCat, 24 of InsulSafe SP (23.5 on the chart) or 71 of SANCTUARY cellulose (70.8). With R-19 already in place you add R-30: 15, 14 or 39 bags for the same 1,000 sq ft.
How many square feet does a bag of blown-in insulation cover?+
It depends on the product and the R-value. On the makers' charts, AttiCat (27.5 lb) covers 110.7 sq ft at R-19, 68.5 at R-30 and 39.9 at R-49; InsulSafe SP (31 lb) covers 116.2, 72.5 and 42.6; GreenFiber SANCTUARY cellulose (25 lb) covers 44.2, 25.9 and 14.1. Online calculators that use a single coverage figure therefore give answers that differ by a factor of two or more.
How deep should blown-in insulation be for R-49?+
At least 17 in of AttiCat, 18.25 in of InsulSafe SP or 14.3 in of SANCTUARY cellulose, which settles to 13.3 in. R-60 takes 20.5, 21.75 and 17.3 in. Loose fiberglass needs more depth than cellulose for the same R-value but far less weight: the charts ask for at least 0.688 lb per sq ft of AttiCat at R-49 against 1.77 lb of SANCTUARY.
What R-value should my attic have?+
For an attic with no insulation, ENERGY STAR's retrofit table (based on the 2021 IECC) recommends R-30 in climate zone 1, R-49 in zones 2 and 3 and R-60 in zones 4 to 8. When 3–4 in is already there, it suggests adding R-25, R-38 or R-49. Floors over unheated space get R-13 to R-38 depending on the zone. Your local code is the legal minimum.
How many batts do I need for a wall?+
Divide the wall area, minus windows and doors, by the area one batt fills: stud spacing × batt length. A 40 ft wall 8 ft high is 320 sq ft. R-13 batts 15 × 93 in in 16 in bays fill 10.33 sq ft each, so 31 batts, or 3 packages of 11 from Owens Corning's EcoTouch chart. Dividing by the 106.6 sq ft printed on the package would say 4, because the label counts the batt face only, not the studs between batts.
Should I add 10% for settling?+
Not on top of a maker's chart: the charts already state the depth after settling, the same as the installed depth for the two fiberglass products and 90% of it for SANCTUARY cellulose. Add a few percent only for uneven joists or a blower you have not used before; GreenFiber notes that job conditions and machine settings can change coverage by as much as 10%.
Semantic next steps
Continue the calculation
These links move to a different input, formula or project stage rather than a keyword variation of this page.
Drywall Calculator — Sheets, Area & Waste
Estimate drywall sheets from rectangular room wall dimensions with an optional ceiling, subtract openings, add waste and use the entered sheet coverage.
Heating Load Calculator — U-Value & Heater Size
Estimate design heating load from envelope UA loss plus infiltration, with watts, BTU/h, kW and a configurable sizing margin.
Furnace Size Calculator — Heating Load & BTU/h
Convert a design heating load into required furnace input capacity from AFUE/thermal efficiency and sizing margin.
Roofing Material Calculator — Squares, Shingles & Underlayment
Turn footprint and roof pitch into sloped roof area, then estimate roofing squares, shingle bundles and underlayment rolls with explicit waste.
Thermal Resistance Calculator — R & Heat Rate
Calculate plane-wall conduction thermal resistance and heat rate from thickness, conductivity, area and temperature difference.
Square Footage Calculator
Calculate square footage for rectangles, circles and triangles, convert the area to square meters and estimate cost from a price per square foot.
Area Calculator — Rectangle, Triangle, Circle, Trapezoid & More
Calculate area for rectangle, square, triangle, circle, trapezoid, parallelogram, ellipse and sector shapes with editable units, converted output units and the substituted formula shown.
Feet and Inches Calculator
Add, subtract, multiply, divide or convert feet and inches, including decimal and fractional inch inputs, with decimal feet and metric equivalents.
More in this calculator collection
Browse nearby calculators in the same topic cluster so related pages reinforce each other instead of sitting as isolated URLs.
Free publisher widget
Put this calculator on your website
Give readers the live calculator without rebuilding the math. Copy the responsive embed in one click, or customize width, height, border and corner radius before publishing. The branded MAXScanner attribution stays visible.
Calculator embed HTML
Paste this code into your page. Focus the code box to select it manually.
Keep the result connected to the real job
MAXScanner keeps the formula and assumptions beside the result so you can verify the number before using it in a drawing, estimate, specification, worksheet or document. Where a supplier, manufacturer, drawing or applicable standard owns a requirement, that source remains authoritative.